- Date
- 12/27/2017
- W/O
- 0681219
- Weather
- Dry
- Operator/Surveyor
- REVELES
- Sewer ID
- Z00479
- PipeID
- P07282
- Time
- 12:40 AM
- Certificate
- U-115-06022630
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Jetting
- Media Label
- H0707
- Sewer Name
- 05 MADISON STREET TRUNK
- City
- Lomita
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Maintenance Related
- Project
- 12272017VMR_MADISON_STREET_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 05 2142
- Downstream MH
- 05 2141
- Dir. of Survey
- Downstream
- Length Surveyed
- 163.1 ft.
- Total Length
- 163.1 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 2
- O&M Quick
- 2A11
- O&M Rating
- 23
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 23
Pipe schematic from manhole 05 2142 to 05 2141 Observation photos (5)

13.7 ft. - Roots Tap Joint, from 11 to 01 o'clock, 5 %, within 8 inches of joint: YESR

19.1 ft. - Roots Tap Joint, from 10 to 11 o'clock, 5 %, within 8 inches of joint: YESR

50.2 ft. - Roots Tap Joint, at 01 o'clock, 5 %, within 8 inches of joint: YESR

61.7 ft. - Roots Tap Joint, from 11 to 01 o'clock, 10 %, within 8 inches of joint: YESR

70.6 ft. - Roots Tap Joint, from 11 to 01 o'clock, 15 %, within 8 inches of joint: YESR