- Date
- 09/20/2018
- W/O
- 0730226
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00075
- PipeID
- P22104
- Time
- 1:18 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0073
- Sewer Name
- B JOINT OUTFALL B - UNIT 1D
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- 20180919_JOINT_OUTFALL_B_UNIT_1D
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 54 in.
- Upstream MH
- H 0344
- Downstream MH
- B 0185
- Dir. of Survey
- Upstream
- Length Surveyed
- 3.9 ft.
- Total Length
- 3.9 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole H 0344 to B 0185 Observation photos (2)

2 ft. - General Observation - MONITORING RING IN PLACE

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG