Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2017, 10:19 AM
  • 01 1127_01 1126_01032017_021133.mp4

Date
03/01/2017
W/O
619125
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00210
PipeID
P01979
Time
2:19 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
4362
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
WO_619125_TV01246_FEB2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 1127
Downstream MH
01 1126
Dir. of Survey
Downstream
Length Surveyed
286.1 ft.
Total Length
286.1 ft.
Structural Index
3
Structural Quick
3J00
Structural Rating
162
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
162
Pipe schematic from manhole 01 1127 to 01 1126
MH: 01 1127MH: 01 1126downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 11273.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES18.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"25.6 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES27.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"73.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"111.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"121.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"152.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"163 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"199 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"245 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"254.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"282.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"286.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish286.1 ft. AMH - Downstream Manhole, Survey Ends - 01 1126

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    25.6 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    27.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
18.5TB
0MWM
27.2CM
73.2TF
163TF
25.6CM
111.6TF
121.8TF
3.6CM
286.1CM
245TF
0MGOCONNECTION AT MH 3 O'CLOCK
282.9TF
0MGOCONNECTION AT MH 9 O'CLOCK
254.9TF
199TFA
0MWL
70.3TF
188.3TF
286.1AMH01 1126
152.4TFA
0AMH01 1127

Properties (4)

additional_info
SC306874
custom_field_two
3
customer
LACSD
datetime
2017-03-01T02:19:33-08:00