Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2017, 11:00 AM
  • 02 1310_02 1309 _28112017_030046.mp4

Date
11/28/2017
W/O
673943
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03830
Time
3:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5052
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_673943_TV02329_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1310
Downstream MH
02 1309
Dir. of Survey
Downstream
Length Surveyed
332 ft.
Total Length
332.1 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
202
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
202
Pipe schematic from manhole 02 1310 to 02 1309
MH: 02 1310MH: 02 1309downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13100 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES9.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start14.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"27.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"60.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"65.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"83.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"86.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"127.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"173.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"189.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"189.9 ft. FM - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES191.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"233.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"261.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"287.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"313.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"327.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"332.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish332.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1309

Observation photos (3)

  • Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    3.1 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

    189.9 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
191.7TB
287.4TF
91.1TB
173.9TF
233.1TF
0AMH02 1310
14.6TF
3.1CM
261.6TF
184.1TFC
9.5CM
0MWM
60.8TF
189.9FM
0MWL
313.4TF
332.1CM
83.9TF
189.4TF
327.9TFC
332.1AMH02 1309
127.5TF
65.5TF
27.5TFC
86.8TFC

Properties (4)

additional_info
SC346281
custom_field_two
3
customer
LACSD
datetime