Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2018, 12:48 PM
  • E 0046_E 0045_192018_050325.mp4

Date
01/09/2018
W/O
#
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00028
PipeID
P11273
Time
4:48 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
H0721
Sewer Name
E JOINT OUTFALL E - UNIT 2
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
20180109MDM_JOINT_OUTFALL_E_UNIT_2
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
E 0045
Downstream MH
E 0046
Dir. of Survey
Upstream
Length Surveyed
134.8 ft.
Total Length
134.8 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole E 0045 to E 0046
MH: E 0045MH: E 0046upstream0 ft. MSA - Survey Abandoned - 10% SLUDGE & ROCK0.4 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - SLUDGE0.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING CONCRETE44.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE UNDER MAG COAT132.8 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - SLUDGE132.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE132.8 ft. MGO - General Observation - MAG COAT 80% START 8:00 TO 4:00134.8 ft. MWL - Water Level, 10 %of cross sectional area134.8 ft. MWM - Water Mark, 20 %of cross sectional area134.8 ft. AMH - Downstream Manhole, Survey Begins - 5:00AM

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

  • General Observation - MAG COAT 80% START 8:00 TO 4:00

    2 ft. - General Observation - MAG COAT 80% START 8:00 TO 4:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE UNDER MAG COAT

    90.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE UNDER MAG COAT

Observations (10)

DistanceCodeObservation
2DSZSLUDGE
2SSSFLAKING CONCRETE
134.4DSZSLUDGE
90.4SSSFLAKING CONCRETE UNDER MAG COAT
134.4SSSFLAKING CONCRETE
2MGOMAG COAT 80% START 8:00 TO 4:00
134.8MSA10% SLUDGE & ROCK
0MWL
0MWM
0AMH5:00AM

Properties (2)

customer
LACSD
datetime