Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 29, 2018, 12:36 PM
  • 29 0194_29 0193 _29012018_045254.mp4

Date
01/29/2018
W/O
684976
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01025
PipeID
P24092
Time
4:36 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5425
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_684976_TV29048_FEB2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0194
Downstream MH
29 0193
Dir. of Survey
Downstream
Length Surveyed
342 ft.
Total Length
342 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0194 to 29 0193
MH: 29 0194MH: 29 0193downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 01940 ft. MWL - Water Level, 5 %of cross sectional area2 ft. MGO - General Observation - SPALLING FROM 8 TO 4 O'CLOCK @ 2' MARK TO 340'3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES12.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start77.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"83.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"125.4 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"128.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"182 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"233.3 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"235.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"281.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"283.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"307.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"331 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"333.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"337.1 ft. TS - Tap Saddle, at 03 o'clock, -, within 8 inches of joint: NO, 6"338.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish342 ft. AMH - Downstream Manhole, Survey Ends - 29 0193

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    12.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle, at 03 o'clock, -, within 8 inches of joint: NO, 6"

    337.1 ft. - Tap Saddle, at 03 o'clock, -, within 8 inches of joint: NO, 6"

Observations (22)

DistanceCodeObservation
342AMH29 0193
283.6TFC
125.4TFC
0MWM
233.3TF
3.1CM
337.1TS
0AMH29 0194
0MWL
281.1TFC
235.9TF
77.9TF
182TF
307.2TFC
338.8CM
128.1TF
331TFC
83.3TF
12.6CM
333.4TF
173.1TF
2MGOSPALLING FROM 8 TO 4 O'CLOCK @ 2' MARK TO 340'

Properties (4)

additional_info
SC347060
custom_field_two
3
customer
LACSD
datetime
2018-01-29T04:36:26-08:00