Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2016, 05:31 AM
  • 01 0191_01 0190_30082016_223722.mpg

Date
08/30/2016
W/O
585995
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01232
Time
10:31 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3576
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
WO_585995_TV01012_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0191
Downstream MH
01 0190
Dir. of Survey
Downstream
Length Surveyed
90.6 ft.
Total Length
90.6 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0191 to 01 0190
MH: 01 0191MH: 01 0190downstream0 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 01910 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area9.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"10.8 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES13.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start63.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"85.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish90.6 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK90.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0190

Observation photos (2)

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    10.8 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    13.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
90.6MGOLATERAL AT MH 9 OCLOCK
72.6TFC
9.3TF
63.9TFC
0MGOLATERAL AT MH 3 OCLOCK
10.8CM
0AMH01 0191
0MWM
90.6AMH01 0190
85.6CM
13.4CM
0MWL

Properties (4)

additional_info
SC306166
custom_field_two
3
customer
LACSD
datetime
2016-08-30T22:31:26-07:00