- Date
- 12/05/2017
- W/O
- 674024
- Weather
- Dry
- Operator/Surveyor
- ERUIZ
- Sewer ID
- Z00316
- PipeID
- P07918
- Time
- 11:00 PM
- Certificate
- 123456
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5152
- Sewer Name
- A JOA-1A DISTRICT 21 INTERCEPTOR
- City
- POMONA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- WO_674024_TV21041_DEC2017
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- A 0709
- Downstream MH
- A 0708
- Dir. of Survey
- Downstream
- Length Surveyed
- 295.4 ft.
- Total Length
- 295.4 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole A 0709 to A 0708 Observation photos (2)

21.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

235.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start