22 0462_22 0461_1112018_005843.mp4
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
18.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
33.3 ft. - General Observation - MAG COAT 20% START 8:00 TO 4:00
49.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
49.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
248.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 0 | MWL | — |
| 248.4 | SSS | PEELING CONCRETE |
| 49.3 | SAP | SEVERE AGG SPORATIC |
| 2 | SSS | PEELING CONCRETE |
| 0 | AMH | 12:50AM |
| 18.7 | SAV | SEVERE AGG |
| 381.3 | SAV | SEVERE AGG |
| 49.9 | SSS | PEELING CONCRETE |
| 381.3 | SSS | PEELING CONCRETE |
| 33.3 | MGO | MAG COAT 20% START 8:00 TO 4:00 |
| 2 | SAV | SEVERE AGG |
| 381.8 | AMH | 1:30AM |
| 381.3 | MGO | MAG COAT 20% FINISH |
| 239.2 | TFC | Capped |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 188.8 | TF | Active |
| 381.3 | SAP | SEVERE AGG SPORATIC |