Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2017, 05:24 AM
  • H 0196_H 0195 _040617_223754.mp4

Date
04/06/2017
W/O
624328
Weather
Dry
Operator/Surveyor
JUAN B
Sewer ID
Z00169
PipeID
P11220
Time
10:24 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
4343
Sewer Name
H JOINT OUTFALL H - UNIT 2C
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
WO_624328_TV02168_MAR2017
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
H 0196
Downstream MH
H 0195
Dir. of Survey
Downstream
Length Surveyed
450.5 ft.
Total Length
450.5 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole H 0196 to H 0195
MH: H 0196MH: H 0195downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 01966 ft. LR - Alignment Right, 20 %, Start6.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start6.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start66.4 ft. LR - Alignment Right, 20 %, Finish450.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish450.5 ft. AMH - Downstream Manhole, Survey Ends - H 0195450.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observations (10)

DistanceCodeObservation
450.5DAGS
6.3SAV
6LR
450.5AMHH 0195
66.4LR
0MWM
0MWL
450.5SAV
0AMHH 0196
6.3DAGS

Properties (4)

additional_info
S340707
custom_field_two
3
customer
LACSD
datetime
2017-04-06T22:24:24-07:00