- Date
- 03/31/2016
- W/O
- 563385
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00083
- PipeID
- P08787
- Time
- 11:42 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K3303
- Sewer Name
- B JOINT OUTFALL B - UNIT 1J
- City
- ROSEMEAD
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- WO_563385_TV15176_APRIL2016
- Sewer Type
- GRAVITY
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Upstream MH
- B 0296
- Downstream MH
- B 0295
- Dir. of Survey
- Downstream
- Length Surveyed
- 534.1 ft.
- Total Length
- 534.1 ft.
- Structural Index
- 3
- Structural Quick
- 3300
- Structural Rating
- 9
- O&M Index
- 2
- O&M Quick
- 412e
- O&M Rating
- 380
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 389
Pipe schematic from manhole B 0296 to B 0295 Observation photos (6)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

120.2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES, Start

262.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

287.5 ft. - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

531.8 ft. - General Observation - COCKROACHES IN MANHOLE