Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 6, 2016, 08:15 AM
  • 15 0612_15 0611_06042016_011604.mp4

Date
04/06/2016
W/O
563459
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00601
PipeID
P12547
Time
1:15 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3308
Sewer Name
15 DOUBLE AVENUE TRUNK
City
TEMPLE CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_563459_TV15205_APRIL2016
Sewer Type
GRAVITY
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
15 0612
Downstream MH
15 0611
Dir. of Survey
Downstream
Length Surveyed
179.8 ft.
Total Length
179.8 ft.
Structural Index
3
Structural Quick
3F00
Structural Rating
105
O&M Index
2
O&M Quick
2F00
O&M Rating
70
Overall Index
3
Overall Quick
Overall Rating
175
Pipe schematic from manhole 15 0612 to 15 0611
MH: 15 0612MH: 15 0611downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 06120 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"41.9 ft. MGO - General Observation - ABANDONED MH64.8 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"66.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"138.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.7 ft. MGO - General Observation - COCKROACHES IN MANHOLE177.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish177.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish179.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK179.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0611

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ABANDONED MH

    41.9 ft. - General Observation - ABANDONED MH

  • General Observation - COCKROACHES IN MANHOLE

    177.7 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (17)

DistanceCodeObservation
24.9TFA
138.8TFC
177.7MGOCOCKROACHES IN MANHOLE
177.7SAP
66.8TFA
0AMH15 0612
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
64.8TBA
123.9TFA
179.8MGOACTIVE CONNECTION AT MH 3 O'CLOCK
41.9MGOABANDONED MH
2DAGS
0MWM
0MWL
2SAP
177.7DAGS
179.8AMH15 0611

Properties (4)

additional_info
SC305435
custom_field_two
3
customer
LACSD
datetime
2016-04-06T01:15:36-07:00