05 0900_05 0899 _05102017_025104.mp4
3.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES
20.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
78.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
91.2 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES
93.2 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES
96 ft. - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES
98.2 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 312.2 | CM | — |
| 315.9 | AMH | 05 0899 |
| 91.2 | CM | — |
| 96 | CL | — |
| 200.5 | TF | — |
| 3.1 | CL | — |
| 0 | AMH | 05 0900 |
| 315.9 | MGO | CONNECTION AT MH 3 O'CLOCK, ACTIVE |
| 97.2 | TF | — |
| 99.5 | TF | — |
| 93.2 | CM | — |
| 302.1 | TF | — |
| 198.1 | TF | — |
| 152.8 | TFD | BROKEN |
| 150.1 | TF | — |
| 246.1 | TF | — |
| 45 | MGO | GASKET HANGING |
| 98.2 | CM | — |
| 0 | MGO | CONNECTION AT MH 9 O'CLOCK, ACTIVE |
| 314 | MGO | SPALLING THROUGHOUT THE REACH |
| 0 | MWL | — |
| 248.8 | TF | — |
| 44.2 | TF | — |
| 20.5 | CM | — |
| 0 | MWM | — |
| 78.8 | CM | — |