- Date
- 10/04/2017
- W/O
- 663253
- Weather
- Dry
- Operator/Surveyor
- R.VARGAS
- Sewer ID
- Z00025
- PipeID
- P00535
- Time
- 1:02 AM
- Certificate
- U-209-211
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K4284
- Sewer Name
- 08 216TH STREET RELOCATION TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Routine Assessment
- Project
- WO_663253_TV08140_OCT2017
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 48 in.
- Upstream MH
- 08 0463
- Downstream MH
- 08 0477
- Dir. of Survey
- Downstream
- Length Surveyed
- 775.3 ft.
- Total Length
- 775.3 ft.
- Structural Index
- 4
- Structural Quick
- 5h3^
- Structural Rating
- 1479
- O&M Index
- 2
- O&M Quick
- 4112
- O&M Rating
- 6
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 1485
Pipe schematic from manhole 08 0463 to 08 0477 Observation photos (8)

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COAT START

2 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

9 ft. - Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

16.6 ft. - Broken, from 02 to 04 o'clock, within 8 inches of joint: YES

102.5 ft. - General Photograph - MISSING PIPE

162.7 ft. - General Photograph

180.2 ft. - General Photograph