Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 29, 2018, 07:29 AM
  • 18 0097_18 0096_8292018_003810.mp4

Date
08/29/2018
W/O
0725903
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00698
PipeID
P13917
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0961
Sewer Name
18 SANTA FE STREET TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
20180829MDM_SANTA_FE_STREET_TRUNK
Material
NRCP
Shape
Circular
Height
12 in.
Upstream MH
18 0096
Downstream MH
18 0097
Dir. of Survey
Upstream
Length Surveyed
383.6 ft.
Total Length
383.6 ft.
Structural Index
3
Structural Quick
4532
Structural Rating
34
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole 18 0096 to 18 0097
MH: 18 0096MH: 18 0097upstream0 ft. AMH - Downstream Manhole, Survey Ends - 1:25AM0.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - PEELING CONCRETE SEVERE AGG ATTACHED0.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING FLAKING CONCRETE0.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG0.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - MODERATE & SEVERE AGG11.6 ft. MWM - Water Mark, 50 %of cross sectional area29.4 ft. MGO - General Observation - ABANDONED MH57.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE SEVERE AQGG ATTACHED63.8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG126.6 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YESR - 1%199.5 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - SLIGHT210.8 ft. MGP - General Photograph211.4 ft. SAM - Surface Aggregate Missing, from 12 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG221.2 ft. RFJ - Roots Fine Joint, from 12 to 02 o'clock, within 8 inches of joint: YESR - 3%261.8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG326.3 ft. MGO - General Observation - 12" VCP330.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING FLAKING CONCRETE357.7 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - SLIGHT363.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO375.6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG381.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MODERATE AGG SPORATIC381.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE383.6 ft. AMH - Downstream Manhole, Survey Begins - 12:35AM383.6 ft. MWL - Water Level, 10 %of cross sectional area383.6 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (12)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MODERATE AGG  SPORATIC

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MODERATE AGG SPORATIC

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    8 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO

    20.4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING FLAKING CONCRETE

    53.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING FLAKING CONCRETE

  • General Observation - 12" VCP

    57.3 ft. - General Observation - 12" VCP

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    121.8 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Missing, from 12 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    172.2 ft. - Surface Aggregate Missing, from 12 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Photograph

    172.8 ft. - General Photograph

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    319.8 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE SEVERE AQGG ATTACHED

    325.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE SEVERE AQGG ATTACHED

  • General Observation - ABANDONED MH

    354.2 ft. - General Observation - ABANDONED MH

Observations (25)

DistanceCodeObservation
57.3MGO12" VCP
0AMH12:35AM
354.2MGOABANDONED MH
0MWL
319.8SAMSEVERE AGG
121.8SAMSEVERE AGG
383SSSPEELING CONCRETE SEVERE AGG ATTACHED
172.2SAMSEVERE AGG
383SSSPEELING FLAKING CONCRETE
383.6AMH1:25AM
184.1FCSLIGHT
372MWM
0MWM
2SAVMODERATE AGG SPORATIC
53.1SSSPEELING FLAKING CONCRETE
383SAMSEVERE AGG
325.9SSSPEELING CONCRETE SEVERE AQGG ATTACHED
257RFJ1%
172.8MGP
162.4RFJ3%
25.9FLSLIGHT
2SSSPEELING FLAKING CONCRETE
383SAVMODERATE & SEVERE AGG
20.4SAM
8SAMSEVERE AGG

Properties (4)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
1
customer
LACSD
datetime
2018-08-29T00:29:46-07:00