Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 29, 2018, 11:31 AM
  • 29 0178_29 0177_8292018_045233.mp4

Date
08/29/2018
W/O
#
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00354
PipeID
P24074
Time
4:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0962
Sewer Name
29 28TH STREET TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
20180829MDM_28TH_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
29 0177
Downstream MH
29 0178
Dir. of Survey
Upstream
Length Surveyed
244.9 ft.
Total Length
244.9 ft.
Structural Index
2
Structural Quick
3729
Structural Rating
39
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
39
Pipe schematic from manhole 29 0177 to 29 0178
MH: 29 0177MH: 29 0178upstream0 ft. AMH - Upstream Manhole, Survey Ends - 5:55AM COMPLETED REVERSE INSPECTION)0.6 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE 20% AT JOINTS0.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE 90% AT JOINTS0.6 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - SLIGHT 5% AT JOINTS0.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT 10% AT JOINTS78.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active80.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped106.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - H106.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Finish - H148.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H148.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H177.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped179.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped183.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Finish - H183.3 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Finish - H188 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H188 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H215.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS215.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS215.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS215.5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS219.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H221.8 ft. FC - Fracture Circumferential, from 08 to 03 o'clock, within 8 inches of joint: YES - H224.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H228.2 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H231 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - H234 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT236.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - H239.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE244.9 ft. MWM - Water Mark, 20 %of cross sectional area244.9 ft. AMH - Downstream Manhole, Survey Begins - 4:50AM244.9 ft. MWL - Water Level, 5 %of cross sectional area244.9 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active

Observation photos (4)

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H

    56.9 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H

    56.9 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H

    96.6 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H

    96.6 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H

Observations (33)

DistanceCodeObservation
61.6FLH
23.1FCH
0MWM
244.3FLHAIRLINE 20% AT JOINTS
20.1FCH
29.4FCSLIGHT AT JOINTS
0AMH4:50AM
29.4FLSLIGHT AT JOINTS
16.7FCH
244.9AMH5:55AM COMPLETED REVERSE INSPECTION)
166.7TFActive
67.1TFCCapped
164.4TFCCapped
65TFCCapped
244.3FCHAIRLINE 90% AT JOINTS
244.3FLSLIGHT 5% AT JOINTS
5FCHAIRLINE
138.2FLH
29.4FLHAIRLINE AT JOINTS
8FCH
0MWL
13.9FCH
29.4FCHAIRLINE AT JOINTS
25.8FLH
0MGOConn. @ Mh, 9 O' Clock. Active
138.2FLH
96.6FLH
61.6FLH
96.6FLH
56.9FLH
10.9FCSLIGHT
244.3FCSLIGHT 10% AT JOINTS
56.9FLH

Properties (4)

custom_field_three
HAIRLINE FRACTURE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime