Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 28, 2018, 08:22 AM
  • 01 1104_01 1103_8282018_014122.mp4

Date
08/28/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01954
Time
1:22 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0956
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
20180828MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1103
Downstream MH
01 1104
Dir. of Survey
Upstream
Length Surveyed
210.9 ft.
Total Length
210.9 ft.
Structural Index
3
Structural Quick
423C
Structural Rating
106
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
112
Pipe schematic from manhole 01 1103 to 01 1104
MH: 01 1103MH: 01 1104upstream0 ft. AMH - Upstream Manhole, Survey Ends - 2:30AM3.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 10" - Open4.5 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H8.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open12.1 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H19.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H19.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H25.3 ft. MWM - Water Mark, 30 %of cross sectional area32.6 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H34.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H34.8 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SL46.3 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open-90% GREASE47.7 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SL49.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H52.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H55 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H65.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H65.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H73.2 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SL78.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - H87.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL91.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active98.6 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SLIGHT98.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL100.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H113.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H116.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H131.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H132.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL133.4 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SL134.7 ft. B - Broken, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE137.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL143.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open143.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H149.3 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SL162.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H183 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H185 ft. MWM - Water Mark, 60 %of cross sectional area188.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES - H192.5 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SL193.1 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H193.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SL193.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open194.9 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H195.8 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H195.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL198.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT198.2 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H198.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H198.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H202.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H202.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - HAIRLINE202.9 ft. MGO - General Observation - 18" VCP202.9 ft. MGO - General Observation - 18210.9 ft. AMH - Downstream Manhole, Survey Begins - 1:50AM210.9 ft. MWM - Water Mark, 40 %of cross sectional area210.9 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (5)

  • General Observation - 18" VCP

    8 ft. - General Observation - 18" VCP

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

    73.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

  • Broken, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE

    76.2 ft. - Broken, from 11 to 12 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

    112.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - H

    132 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - H

Observations (57)

DistanceCodeObservation
67.3TFOpen
176.1FLH
112.3FCSLIGHT
145.8FLH
8FLH
206.4FCH
158.2FLH
8FLHAIRLINE
0AMH1:50AM
15.1FCH
112.3FLSL
164.6TFDOpen-90% GREASE
137.7FCSL
0MWM
97.3FLH
67.1FLH
198.8FCH
185.6MWM
110FLH
79.2FLH
78.4FLSL
210.9AMH2:30AM
178.3FCH
12.7FLSLIGHT
8MGO18" VCP
27.9FLH
191.3FLH
155.9FLH
73.8FLSL
25.9MWM
163.2FCSL
17.8FCH
17TFOpen
123.1FLSL
0MWL
15.1FLSL
207.7TBOpen
191.3FCH
61.6FCSL
145.8FLH
16FCH
12.7FCH
17.8FCSL
76.2BSLIGHT FRACTURE
48.3FLH
12.7FLH
12.7FLH
94.3FLH
176.1FCSL
161.6FLH
18.4FCSL
119TFActive
202.5TFOpen
77.5FCSL
8MGO18
132FLH
22.8FMH

Properties (4)

custom_field_three
BROKEN PIPE SLIGHT FRACTURE
custom_field_two
2
customer
LACSD
datetime