Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 28, 2018, 07:27 AM
  • 01 1080_01 1111_8282018_003637.mp4

Date
08/28/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00210
PipeID
P01962
Time
12:27 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0956
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
20180828MDM_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1111
Downstream MH
01 1080
Dir. of Survey
Upstream
Length Surveyed
347.8 ft.
Total Length
347.8 ft.
Structural Index
3
Structural Quick
3A27
Structural Rating
44
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 01 1111 to 01 1080
MH: 01 1111MH: 01 1080upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:05AM0.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active-OUTGOING4.5 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL32.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL36.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open48.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H74.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H74.5 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - H80.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active86.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open120.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H131 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - H134.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open134.7 ft. TBB - Tap Break-In Abandoned, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open139.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped146.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H183.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open183.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL185.2 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open188.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped192.9 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H192.9 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - H237.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open242 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H260.2 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H284.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open287 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open290.9 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - HAIRLINE294.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open334.3 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - SL337 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SLIGHT337 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL339.3 ft. MGO - General Observation - 18" VCP347.8 ft. MWM - Water Mark, 30 %of cross sectional area347.8 ft. AMH - Downstream Manhole, Survey Begins - 12:35AM347.8 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (1)

  • General Observation - 18" VCP

    8.5 ft. - General Observation - 18" VCP

Observations (36)

DistanceCodeObservation
208TFCCapped
154.9FCH
216.8FCH
63.7TFOpen
159.3TFCCapped
0MWM
60.8TFOpen
347.3MGOConn. @ Mh, 9 O' Clock. Active-OUTGOING
53.4TFOpen
8.5MGO18" VCP
314.9FLSL
164.7TFOpen
87.6FLH
164.7FLSL
162.6TBOpen
201.6FLH
10.8FCSLIGHT
105.8FLH
56.9FLHAIRLINE
261.7TFOpen
311.2TFOpen
343.3FCSL
0AMH12:35AM
299.5FLH
213.1TFOpen
0MWL
10.8FCSL
213.1TBBOpen
154.9FLH
267.3TFActive
13.5FCSL
347.8AMH1:05AM
273.3FLH
110.1TFOpen
227.1FLH
273.3FCH

Properties (4)

custom_field_three
FEW SLIGHT FRACTURES
custom_field_two
4
customer
LACSD
datetime
2018-08-28T00:27:29-07:00