- Date
- 08/27/2018
- W/O
- 0723688
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00210
- PipeID
- P02232
- Time
- 1:47 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0955
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- 20180827MDM_HUNTINGTON_PARK_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 01 1135
- Downstream MH
- H 0136
- Dir. of Survey
- Downstream
- Length Surveyed
- 55.6 ft.
- Total Length
- 55.6 ft.
- Structural Index
- 2
- Structural Quick
- 3326
- Structural Rating
- 21
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 23
Pipe schematic from manhole 01 1135 to H 0136 Observation photos (3)

8 ft. - General Observation - 15" VCP

55 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - THROUGHOUT REACH

55.6 ft. - Downstream Manhole, Survey Ends - 2:20AM