Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 24, 2018, 10:43 AM
  • 01 1108_01 1107_8242018_034536.mp4

Date
08/24/2018
W/O
0723688
Weather
Dry
Operator/Surveyor
Reveles
Sewer ID
Z00210
PipeID
P01958
Time
3:43 AM
Certificate
U-115-06022633
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0953
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK TRUNK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
08242018ROIII_Huntington_Park_Trunk
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 1108
Downstream MH
01 1107
Dir. of Survey
Downstream
Length Surveyed
327.3 ft.
Total Length
327.3 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
9
O&M Index
3
O&M Quick
4123
O&M Rating
10
Overall Index
2
Overall Quick
Overall Rating
19
Pipe schematic from manhole 01 1108 to 01 1107
MH: 01 1108MH: 01 1107downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 03: 46 AM2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Start29.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES37.7 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Roots87.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4" - Open132.3 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4" - roots188.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open199.5 ft. CC - Crack Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES199.5 ft. CC - Crack Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES244.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Open288 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"300.4 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES320.5 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES324 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES, Finish324 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES, Finish327.3 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4" - Possible Drop Connection327.3 ft. AMH - Downstream Manhole, Survey Ends - 04:20 AM

Observation photos (2)

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Roots

    37.7 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - Roots

  • Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4" - roots

    132.3 ft. - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 4" - roots

Observations (21)

DistanceCodeObservation
288TFA
87.1TFOpen
37.7TFDRoots
0MWM
320.5CL
199.5CC
2DAGS
0TFC
0MWL
0AMH03: 46 AM
327.3TFCPossible Drop Connection
132.3TFAroots
300.4FL
327.3AMH04:20 AM
324DAGS
199.5CC
244.2TFOpen
2DAGS
29.3CL
324DAGS
188.3TFOpen

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2018-08-24T03:43:27-07:00