- Date
- 08/07/2018
- W/O
- 717875
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00202
- PipeID
- P01248
- Time
- 4:02 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5972
- Sewer Name
- 01 COMPTON AVENUE TRUNK
- City
- LOS ANGELES
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_717875_TV01262_AUG2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 01 0206
- Downstream MH
- 01 0205
- Dir. of Survey
- Downstream
- Length Surveyed
- 336.9 ft.
- Total Length
- 336.9 ft.
- Structural Index
- 3
- Structural Quick
- 4J3L
- Structural Rating
- 423
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 423
Pipe schematic from manhole 01 0206 to 01 0205 Observation photos (5)

2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

9.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

35.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

318 ft. - Material Change, Vitrified clay pipe

325.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start