Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2018, 06:11 AM
  • 18 0559_18 0557 _09082018_232654.mp4

Date
08/09/2018
W/O
717823
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00685
PipeID
P14408
Time
11:11 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5979
Sewer Name
18 LA MIRADA RELIEF TRUNK
City
SANTA FE SPRINGS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Routine Assessment
Project
WO_717823_TV18082_AUG2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
18 0559
Downstream MH
18 0557
Dir. of Survey
Downstream
Length Surveyed
410.3 ft.
Total Length
410.3 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
240
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
240
Pipe schematic from manhole 18 0559 to 18 0557
MH: 18 0559MH: 18 0557downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 05590 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.6 ft. MGO - General Observation - MAG COAT8.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start241.3 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6"410.3 ft. AMH - Downstream Manhole, Survey Ends - 18 0557410.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
8.2SAV
410.3AMH18 0557
0AMH18 0559
0MWM
0MWL
3.6MGOMAG COAT
410.3SAV
241.3TF

Properties (4)

additional_info
SC364743
custom_field_two
3
customer
LACSD
datetime
2018-08-09T23:11:53-07:00