Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2018, 08:27 AM
  • 01 0270_01 0269_06082018_014211.mp4

Date
08/06/2018
W/O
717715
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01318
Time
1:27 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5966
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_717715_TV01205_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
01 0270
Downstream MH
01 0269
Dir. of Survey
Downstream
Length Surveyed
357.6 ft.
Total Length
357.6 ft.
Structural Index
4
Structural Quick
4M31
Structural Rating
283
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
287
Pipe schematic from manhole 01 0270 to 01 0269
MH: 01 0270MH: 01 0269downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 02700 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK3.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start85.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"136.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"159.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"186.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"209.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"215.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES215.3 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6" - CRACKS243.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"287.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"357.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK357.6 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH357.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0269357.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock,  , within 8 inches of joint: YES

    215.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, at 08 o'clock, , within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
0AMH01 0270
7.1CM
0MWL
357.6MGOCONNECTION AT MH 3 O'CLOCK
357.6MGOCAPPED LATERAL 9 O'CLOCK @ MH
186.3TFC
287.2TF
357.6AMH01 0269
215.3TFDCRACKS
0MWM
136.5TFC
243.6TFC
215.2DAGS
209.9TFC
0MGOCONNECTION AT MH 3 O'CLOCK
7.1FM
3.6CM
113.5TF
85.8TFC
159.6TFC
357.6FM

Properties (4)

additional_info
SC364729
custom_field_two
2
customer
LACSD
datetime