Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2018, 08:14 AM
  • 18 0662_18 0661 _09082018_012622.mp4

Date
08/09/2018
W/O
718121
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00696
PipeID
P14511
Time
1:14 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5975
Sewer Name
18 PHOEBE AVENUE TRUNK
City
LA MIRADA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
36
Purpose
Routine Assessment
Project
WO_718121_TV18169_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
18 0662
Downstream MH
18 0661
Dir. of Survey
Downstream
Length Surveyed
299.7 ft.
Total Length
299.7 ft.
Structural Index
3
Structural Quick
3A24
Structural Rating
44
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
162
Pipe schematic from manhole 18 0662 to 18 0661
MH: 18 0662MH: 18 0661downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 06620 ft. MWM - Water Mark, 25 %of cross sectional area2.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start36.5 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES61.7 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES73.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"78.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"122.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES175.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"181.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"211.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES232.1 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start275.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"279.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"292.4 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Finish296 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish299.7 ft. AMH - Downstream Manhole, Survey Ends - 18 0661

Observation photos (6)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    36.5 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    61.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    122.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    211.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start

    232.1 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
0MWL
2.7DAE
78.7TFC
175.9TFC
275.3TF
0AMH18 0662
36.5CL
296DAE
73.9TF
61.7CL
299.7AMH18 0661
279.9TFC
211.7CL
181.4TF
122.1CL
292.4CM
232.1CM
0MWM

Properties (4)

additional_info
SC364739
custom_field_two
3
customer
LACSD
datetime
2018-08-09T01:14:50-07:00