Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2018, 09:25 AM
  • 01 0230A_01 0230_06082018_024316.mp4

Date
08/06/2018
W/O
717798
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00202
PipeID
P01273
Time
2:25 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5967
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
03
Purpose
Routine Assessment
Project
WO_717798_TV01222_AUG2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
01 0230
Downstream MH
01 0230A
Dir. of Survey
Upstream
Length Surveyed
273.8 ft.
Total Length
273.8 ft.
Structural Index
3
Structural Quick
4D3L
Structural Rating
290
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
290
Pipe schematic from manhole 01 0230 to 01 0230A
MH: 01 0230MH: 01 0230Aupstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 01 0230A0 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish85.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"88.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"117.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start129.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"134.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"138.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES145.8 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES165 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"166 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES182.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"193 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish204.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"208.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"214.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start224.6 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES226.6 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES232.3 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES235.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"248.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"255.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES261.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"270.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start270.2 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES273.8 ft. MWM - Water Mark, 40 %of cross sectional area273.8 ft. MWL - Water Level, 25 %of cross sectional area273.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK273.8 ft. AMH - Downstream Manhole, Survey Begins - 01 0230

Observation photos (11)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    3.6 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    18.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    41.5 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    47.2 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES

    49.2 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    58.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    107.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    128 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    135.7 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    156.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (31)

DistanceCodeObservation
69TF
3.6SAV
47.2FL
135.7FL
58.9CM
273.8MGOCONNECTION AT MH 3 O'CLOCK
188.4TF
139.6TF
3.6FM
107.8FL
273.8SAV
128FL
0MWM
65.5TF
144.2TF
18.3CL
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK
25.6TF
273.8AMH01 0230A
91.7TF
0AMH01 0230
273.8FM
37.9TF
12TF
80.8CM
156.4FM
41.5FL
108.8TF
185.6TF
49.2FL

Properties (4)

additional_info
SC364730
custom_field_two
2
customer
LACSD
datetime
2018-08-06T02:25:15-07:00