Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2018, 11:05 AM
  • 05 1398_05 1397 _26072018_041837.mp4

Date
07/26/2018
W/O
718157
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00487
PipeID
P06619
Time
4:05 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5798
Sewer Name
05 MONETA TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
WO_718157_TV05336_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
05 1398
Downstream MH
05 1397
Dir. of Survey
Downstream
Length Surveyed
322.5 ft.
Total Length
322.5 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
256
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
256
Pipe schematic from manhole 05 1398 to 05 1397
MH: 05 1398MH: 05 1397downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 05 13983.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start61.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"199.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"234.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"285.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"322.5 ft. AMH - Downstream Manhole, Survey Ends - 05 1397322.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK322.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK322.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
285.9TFC
322.5AMH05 1397
0MWL
322.5MGOCONNECTION AT MH 3 O'CLOCK
234.9TFC
199.3TF
0MWM
322.5MGOCONNECTION AT MH 9 O'CLOCK
61.3TFC
0MGOCONNECTION AT MH 3 O'CLOCK
0MGOCONNECTION AT MH 9 O'CLOCK
92.3TF
150.9TFC
322.5FM
0AMH05 1398
3.1FM

Properties (4)

additional_info
SC364710
custom_field_two
2
customer
LACSD
datetime
2018-07-26T04:05:56-07:00