Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 1, 2018, 06:06 AM
  • 18 0827_18 0826 _31072018_233843.mp4

Date
07/31/2018
W/O
717989
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00707
PipeID
P14690
Time
11:06 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5805
Sewer Name
18 SO WHITTIER OUTFALL TR, SECT 5
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
WO_717989_TV18119_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0827
Downstream MH
18 0826
Dir. of Survey
Downstream
Length Surveyed
92.8 ft.
Total Length
92.8 ft.
Structural Index
4
Structural Quick
4C31
Structural Rating
75
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
75
Pipe schematic from manhole 18 0827 to 18 0826
MH: 18 0827MH: 18 0826downstream0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 08270 ft. MWL - Water Level, 5 %of cross sectional area3.1 ft. FS - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES4.6 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start30.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"34.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"80.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"83.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"92.8 ft. AMH - Downstream Manhole, Survey Ends - 18 082692.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK92.8 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

    3.1 ft. - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    4.6 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
0MWM
0AMH18 0827
3.1FS
0MWL
83.3TFC
80.1TFC
30.7TF
92.8AMH18 0826
92.8MGOCONNECTION AT MH 3 O'CLOCK
92.8FM
34.4TFC
4.6FM

Properties (4)

additional_info
SC364718
custom_field_two
2
customer
LACSD
datetime