Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2018, 05:46 AM
  • 15 1097_15 1096 _01052018_230216.mp4

Date
05/01/2018
W/O
696294
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00614
PipeID
P12857
Time
10:46 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5584
Sewer Name
15 MERCED TRUNK, SECTION 1
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
WO_696294_TV15099_APR2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 1097
Downstream MH
15 1096
Dir. of Survey
Downstream
Length Surveyed
190.9 ft.
Total Length
190.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 15 1097 to 15 1096
MH: 15 1097MH: 15 1096downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 10972 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start41.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"78.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"127.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"177 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"190.9 ft. AMH - Downstream Manhole, Survey Ends - 15 1096190.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE190.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
190.9AMH15 1096
0MWM
2DAGS
190.9MGOCOCKROACHES IN MANHOLE
41.7TFC
127.7TFC
0MWL
78.2TFC
177TFC
190.9DAGS
0AMH15 1097

Properties (4)

additional_info
SC358545
custom_field_two
3
customer
LACSD
datetime
2018-05-01T22:46:53-07:00