- Date
- 07/30/2018
- W/O
- 717866
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00037
- PipeID
- P10180
- Time
- 11:05 PM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5801
- Sewer Name
- F JOINT OUTFALL F - UNIT 3B
- City
- CERRITOS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 39A
- Purpose
- Routine Assessment
- Project
- WO_717866_TV02231_AUG2018
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 63 in.
- Width
- 63 in.
- Upstream MH
- F 0148
- Downstream MH
- F 0147
- Dir. of Survey
- Downstream
- Length Surveyed
- 731.9 ft.
- Total Length
- 731.9 ft.
- Structural Index
- 4
- Structural Quick
- 5Z3\
- Structural Rating
- 1113
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 1113
Pipe schematic from manhole F 0148 to F 0147 Observation photos (4)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

29.5 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

157.5 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

320.6 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start