Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2018, 10:45 AM
  • 29 0455_29 0454 _26072018_041048.mpg

Date
07/26/2018
W/O
717991
Weather
Dry
Operator/Surveyor
E. RUIZ
Sewer ID
Z00537
PipeID
P24496
Time
3:45 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5324
Sewer Name
29 21ST STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
WO_717991_TV29055_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0455
Downstream MH
29 0454
Dir. of Survey
Downstream
Length Surveyed
317.1 ft.
Total Length
317.2 ft.
Structural Index
3
Structural Quick
5137
Structural Rating
28
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
28
Pipe schematic from manhole 29 0455 to 29 0454
MH: 29 0455MH: 29 0454downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 045550.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"52.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"66.2 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES147.7 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES148 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"149.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"157.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES171.5 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES204.9 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES239.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES239.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"246.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"263.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES310.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES316.5 ft. B - Broken, from 03 to 09 o'clock, within 8 inches of joint: YES317.2 ft. AOC - Drop Connection, Survey Ends - 29 0454

Observation photos (9)

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    66.2 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    147.7 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    157.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    171.5 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    204.9 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    239.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    263.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    310.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 03 to 09 o'clock, within 8 inches of joint: YES

    316.5 ft. - Broken, from 03 to 09 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
171.5CM
263.1CM
239.6CM
0MWL
310.5CM
66.2CL
317.2AOC29 0454
239.7TFC
50.8TFC
316.5B
0MWM
204.9CM
0AMH29 0455
148TF
52.2TFC
246.4TFA
157.3CM
147.7CM
149.7TF

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2018-07-26T03:45:46-07:00