- Date
- 07/23/2018
- W/O
- 717761
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00528
- PipeID
- P06735
- Time
- 4:03 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5787
- Sewer Name
- 05 TORRANCE EXTENSION TRUNK
- City
- TORRANCE
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- WO_717761_TV05210_AUG2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 05 1513
- Downstream MH
- 05 1512
- Dir. of Survey
- Downstream
- Length Surveyed
- 366 ft.
- Total Length
- 366 ft.
- Structural Index
- 3
- Structural Quick
- 3M00
- Structural Rating
- 216
- O&M Index
- 1
- O&M Quick
- 311F
- O&M Rating
- 39
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 255
Pipe schematic from manhole 05 1513 to 05 1512 Observation photos (3)

6.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

42.5 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

81 ft. - Roots Medium Connection, from 01 to 04 o'clock, 20 %, within 8 inches of joint: NO