Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 25, 2018, 07:47 AM
  • 29 0187_29 0186 _25072018_010516.mpg

Date
07/25/2018
W/O
717713
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z01025
PipeID
P24084
Time
12:47 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5322
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
WO_717713_TV29056_AUG2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0187
Downstream MH
29 0186
Dir. of Survey
Downstream
Length Surveyed
341.3 ft.
Total Length
341.3 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 29 0187 to 29 0186
MH: 29 0187MH: 29 0186downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 01870 ft. MWL - Water Level, 5 %of cross sectional area28.3 ft. FM - Fracture Multiple, from 05 to 07 o'clock, within 8 inches of joint: YES45.4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"75.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"78 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"126.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"129.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"178.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"182.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"203.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"232 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"255.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"266.8 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"279.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"306.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"329.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"341.3 ft. AMH - Downstream Manhole, Survey Ends - 29 0186

Observation photos (1)

  • Fracture Multiple, from 05 to 07 o'clock, within 8 inches of joint: YES

    28.3 ft. - Fracture Multiple, from 05 to 07 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
255.3TFC
279.4TFC
45.4TBA
178.6TFC
306.6TFC
182.4TFC
0MWM
75.5TFC
78TFA
232TFC
329.7TFC
28.3FM
203.8TFC
266.8TBA
126.8TFA
0AMH29 0187
341.3AMH29 0186
129.7TFC
0MWL

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-07-25T00:47:00-07:00