Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2018, 10:06 AM
  • H 0723_H 0722_06072018_032702.mp4

Date
07/06/2018
W/O
712465
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11132
Time
3:06 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5765
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
29
Purpose
Routine Assessment
Project
WO_712465_TV22077_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0723
Downstream MH
H 0722
Dir. of Survey
Downstream
Length Surveyed
663.6 ft.
Total Length
663.6 ft.
Structural Index
3
Structural Quick
3Y00
Structural Rating
396
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
396
Pipe schematic from manhole H 0723 to H 0722
MH: H 0723MH: H 0722downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 07232.7 ft. MGO - General Observation - MAG COAT2.7 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start663.6 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish663.6 ft. AMH - Downstream Manhole, Survey Ends - H 0722

Observation photos (1)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWL
0MWM
2.7MGOMAG COAT
0AMHH 0723
663.6SAV
2.7SAV
663.6AMHH 0722

Properties (4)

additional_info
SC359674
custom_field_two
3
customer
LACSD
datetime
2018-07-06T03:06:03-07:00