Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 2, 2018, 08:42 AM
  • H 0748_H 0747_02072018_020930.mp4

Date
07/02/2018
W/O
712465
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00941
PipeID
P11157
Time
1:42 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5763
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
30
Purpose
Routine Assessment
Project
WO_712465_TV22077_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
22 in.
Width
22 in.
Upstream MH
H 0748
Downstream MH
H 0747
Dir. of Survey
Downstream
Length Surveyed
825.9 ft.
Total Length
825.9 ft.
Structural Index
3
Structural Quick
3`00
Structural Rating
495
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
495
Pipe schematic from manhole H 0748 to H 0747
MH: H 0748MH: H 0747downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 07480 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.9 ft. MGO - General Observation - MAG COAT825.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish825.9 ft. AMH - Downstream Manhole, Survey Ends - H 0747

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWL
825.9SAV
825.9AMHH 0747
0AMHH 0748
2.1SAV
2.9MGOMAG COAT
0MWM

Properties (4)

additional_info
SC359672
custom_field_two
3
customer
LACSD
datetime
2018-07-02T01:42:44-07:00