Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 18, 2018, 08:30 AM
  • E 0067_E 0066_18072018_014626.mp4

Date
07/18/2018
W/O
712464
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00030
PipeID
P11297
Time
1:30 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5782
Sewer Name
E JOINT OUTFALL E - UNIT 4
City
WATTS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_712464_TV01266_JUL2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
E 0067
Downstream MH
E 0066
Dir. of Survey
Downstream
Length Surveyed
333.2 ft.
Total Length
333.2 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
195
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
199
Pipe schematic from manhole E 0067 to E 0066
MH: E 0067MH: E 0066downstream0 ft. AMH - Upstream Manhole, Survey Begins - E 00670 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area5.9 ft. MGO - General Observation - MAG COAT5.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start333.2 ft. AMH - Downstream Manhole, Survey Ends - E 0066333.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMHE 0067
333.2AMHE 0066
5.9MGOMAG COAT
0MWM
0MWL
5.9SAV
333.2SAV

Properties (4)

additional_info
SC359693
custom_field_two
3
customer
LACSD
datetime
2018-07-18T01:30:44-07:00