- Date
- 07/17/2018
- W/O
- 712092
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00351
- PipeID
- P02930
- Time
- 3:13 AM
- Certificate
- U-508-7069
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5779
- Sewer Name
- 02 GARFIELD AVENUE EXTENSION TRUNK
- City
- MONTEBELLO
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_712092_TV02244_JUL2018
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 02 1146
- Downstream MH
- 02 1145
- Dir. of Survey
- Downstream
- Length Surveyed
- 320.1 ft.
- Total Length
- 320.1 ft.
- Structural Index
- 3
- Structural Quick
- 3K21
- Structural Rating
- 188
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 188
Pipe schematic from manhole 02 1146 to 02 1145 Observation photos (2)

7.5 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

10.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start