Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2018, 05:22 PM
  • 05 1180_05 1179_7302018_102407.mp4

Date
07/30/2018
W/O
0717904
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00514
PipeID
P06418
Time
10:22 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7771
Sewer Name
05 ROSECRANS AVENUE TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
20180730SHO_ROSECRANS_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
11.300000190734863 in.
Upstream MH
05 1180
Downstream MH
05 1179
Dir. of Survey
Downstream
Length Surveyed
335.2 ft.
Total Length
335.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2900
O&M Rating
18
Overall Index
2
Overall Quick
Overall Rating
18
Pipe schematic from manhole 05 1180 to 05 1179
MH: 05 1180MH: 05 1179downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 118035.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"38 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"41 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: NO, 6"88.8 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6"91.8 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6"142 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"188.9 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6"192.6 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6"233.5 ft. MGO - General Observation - LINER TAPE IS LOOSE240.2 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6"242.2 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6"296.2 ft. MGO - General Observation - LINER TAPE IS LOOSE297 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"300 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: NO, 6"318.7 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start - DEBRIS335.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Finish - DEBRIS335.2 ft. AMH - Downstream Manhole, Survey Ends - MH 1179335.2 ft. MGO - General Observation - ACTIVE CONENCTION IN THE MH @ 9

Observation photos (3)

  • General Observation - LINER TAPE IS LOOSE

    233.5 ft. - General Observation - LINER TAPE IS LOOSE

  • General Observation - LINER TAPE IS LOOSE

    296.2 ft. - General Observation - LINER TAPE IS LOOSE

  • Deposits Settled Other,  10 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO, Start - DEBRIS

    318.7 ft. - Deposits Settled Other, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO, Start - DEBRIS

Observations (21)

DistanceCodeObservation
297TF
192.6TFD
188.9TFD
300TFD
335.2DSZDEBRIS
318.7DSZDEBRIS
0MWL
88.8TFD
240.2TFD
233.5MGOLINER TAPE IS LOOSE
0MWM
335.2AMHMH 1179
0AMHMH 1180
91.8TFD
35.9TF
296.2MGOLINER TAPE IS LOOSE
335.2MGOACTIVE CONENCTION IN THE MH @ 9
41TFD
242.2TFD
142TFA
38TF

Properties (4)

custom_field_three
LINER IS IN GOOD CONDITION
custom_field_two
4
customer
LACSD
datetime
2018-07-30T10:22:34-07:00