- Date
- 07/06/2017
- W/O
- 613355
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00289
- PipeID
- P18821
- Time
- 12:43 AM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K3980-SC342143
- Sewer Name
- 02 MONTEREY PARK EXTENSION TRUNK
- City
- MONTEREY PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 09
- Purpose
- Routine Assessment
- Project
- WO_613355_TV02105_JUN2017
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 02 1664
- Downstream MH
- 02 1665
- Dir. of Survey
- Upstream
- Length Surveyed
- 125.2 ft.
- Total Length
- 125.2 ft.
- Structural Index
- 4
- Structural Quick
- 4131
- Structural Rating
- 7
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 7
Pipe schematic from manhole 02 1664 to 02 1665 Observation photos (2)

11.5 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

20 ft. - Fracture Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES, Start