Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2018, 05:27 AM
  • B 0730_B 0729 _10072018_224451.mp4

Date
07/10/2018
W/O
712477
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00111
PipeID
P09194
Time
10:27 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5770
Sewer Name
B JOINT OUTFALL B - UNIT 8H
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
02
Purpose
Routine Assessment
Project
WO_712477_TV22165_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
B 0730
Downstream MH
B 0729
Dir. of Survey
Downstream
Length Surveyed
341.4 ft.
Total Length
341.4 ft.
Structural Index
3
Structural Quick
413L
Structural Rating
202
O&M Index
1
O&M Quick
311C
O&M Rating
25
Overall Index
3
Overall Quick
Overall Rating
227
Pipe schematic from manhole B 0730 to B 0729
MH: B 0730MH: B 0729downstream0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - B 07300 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES13.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start34.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"85.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"92.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"94.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"190.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"205.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"225.1 ft. LL - Alignment Left, 10 %, Start226.4 ft. FM - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES280.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"291.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"292 ft. RML - Roots Medium Lateral, at 02 o'clock, 15 %, within 8 inches of joint: NO292.8 ft. RFC - Roots Fine Connection, from 02 to 05 o'clock328.9 ft. LL - Alignment Left, 10 %, Finish337.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish341.4 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK341.4 ft. AMH - Downstream Manhole, Survey Ends - B 0729341.4 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (5)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    3.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Alignment Left, 10 %, Start

    225.1 ft. - Alignment Left, 10 %, Start

  • Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

    226.4 ft. - Fracture Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

  • Roots Fine Connection, from 02 to 05 o'clock

    292.8 ft. - Roots Fine Connection, from 02 to 05 o'clock

Observations (23)

DistanceCodeObservation
34.6TF
0MGOCONNECTION AT MH 3 O'CLOCK
0AMHB 0730
337.1CM
226.4FM
13.2CM
280.6TFC
292.8RFC
291.7TF
190.3TFC
85.4TF
292RML
341.4MGOCONNECTION AT MH 3 O'CLOCK
205.5TF
341.4AMHB 0729
0MWM
225.1LL
328.9LL
3.4CM
0MWL
92.9TF
341.4MGOCONNECTION AT MH 9 O'CLOCK
94.9TFC

Properties (4)

additional_info
SC359679
custom_field_two
3
customer
LACSD
datetime