Section#11_G 0113_G 0086__7252018__ I0040.mp4
2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SWOLLEN BLISTERING CONCRETE
2 ft. - Deposits Settled Other, 60 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - POSSIBLE MISSING TILES UNDER FLOW
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - MISSING TILES 100% START 10:00 TO 2:00
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING
10.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
77.8 ft. - General Observation - 1 ROW REMAINING TILES
92.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR
107 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
107 ft. - General Observation - MISSING TILES 100% 9:00 TO 3:00
107 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR CORRODED & MISSING
107 ft. - General Observation - TOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH
116.6 ft. - General Observation - REMAINING TILES
149.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
169.1 ft. - General Observation - REMAINING TILES
182.5 ft. - General Observation - TILES 50% START
235.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
| Distance | Code | Observation |
|---|---|---|
| 107 | MWM | — |
| 107 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 2 | SSS | SWOLLEN BLISTERING CONCRETE |
| 0 | MWM | — |
| 2 | DSZ | POSSIBLE MISSING TILES UNDER FLOW |
| 107 | SAM | SEVERE AGG |
| 107 | SSS | — |
| 0 | MGO | MH CONN 3:00 ACTIVE |
| 10.5 | SRC | BROKEN MISSING REBAR |
| 107 | MWL | — |
| 77.8 | MGO | 1 ROW REMAINING TILES |
| 0 | MWL | — |
| 107 | MGO | MISSING TILES 100% 9:00 TO 3:00 |
| 322.1 | MGO | MISSING TILES 95% FINISH |
| 0 | AMH | 4:40AM |
| 322.1 | SRC | LONG CIRCUM REBAR CORRODED MISSING |
| 208.6 | MGO | 95% MISSING TILES START |
| 182.5 | MGO | TILES 50% START |
| 110.2 | MGO | 1 ROW TILES |
| 107 | SSS | SWOLLEN BLISTERING CONCRETE |
| 169.1 | MGO | REMAINING TILES |
| 0 | MGO | MH CONN 9:00 ACTIVE |
| 92.7 | SRC | CIRCUM REBAR |
| 322.8 | AMH | 5:20AM |
| 2 | SAM | SEVERE AGG |
| 116.6 | MGO | REMAINING TILES |
| 107 | SRC | LONG CIRCUM REBAR CORRODED & MISSING |
| 2 | MGO | MISSING TILES 100% START 10:00 TO 2:00 |
| 312.2 | MGO | 2 ROWS TILES |
| 322.1 | MGO | MH CONN 3:00 ACTIVE LARGE INCOMING |
| 235.2 | SRC | BROKEN MISSING REBAR |
| 322.1 | SAM | SEVERE AGG |
| 276.8 | MGO | 2 ROWS TILES |
| 2 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING |
| 322.1 | SSS | SWOLLEN BLISTERING CONCRETE |
| 107 | MGO | TOP OF PIPE APPEARS BURNED BY FIRE THROUGHOUT REACH |
| 107 | SAM | SEVERE AGG |
| 149.6 | SRC | BROKEN MISSING REBAR |