Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2018, 08:49 AM
  • 18 0929_18 0928 _28062018_020523.mp4

Date
06/28/2018
W/O
711970
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00700
PipeID
P14777
Time
1:49 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5759
Sewer Name
18 SCOTT AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_711970_TV18118_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
18 0929
Downstream MH
18 0928
Dir. of Survey
Downstream
Length Surveyed
349.9 ft.
Total Length
349.9 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
207
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
207
Pipe schematic from manhole 18 0929 to 18 0928
MH: 18 0929MH: 18 0928downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 09290 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"26.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"31 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"72 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"74.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"122.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"223.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"226.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"274.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"277.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"322.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"325.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"342.6 ft. SZ - Surface Other, at 10 o'clock, within 8 inches of joint: NO - HOLE AT LATERAL343.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"349.9 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH349.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish349.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0928

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Other, at 10 o'clock, within 8 inches of joint: NO - HOLE AT LATERAL

    342.6 ft. - Surface Other, at 10 o'clock, within 8 inches of joint: NO - HOLE AT LATERAL

Observations (25)

DistanceCodeObservation
349.9MGOCAPPED LATERAL 9 O'CLOCK @ MH
349.9CM
175.9TF
24.1TFC
31TB
223.8TF
349.9AMH18 0928
173.1TF
74.7TF
125.4TF
325.2TF
0AMH18 0929
0MGOCONNECTION AT MH 9 O'CLOCK
0MWM
226.6TF
274.6TFC
277.5TF
122.5TF
342.6SZHOLE AT LATERAL
0MWL
343.5TB
322.2TF
26.9TFC
3.1CM
72TF

Properties (4)

additional_info
SC359668
custom_field_two
3
customer
LACSD
datetime
2018-06-28T01:49:24-07:00