Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 28, 2018, 09:38 AM
  • 18 0926_18 0925 _28062018_031254.mp4

Date
06/28/2018
W/O
711900
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00700
PipeID
P14774
Time
2:38 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5758
Sewer Name
18 SCOTT AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
WO_711900_TV18047_JUL2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
18 0926
Downstream MH
18 0925
Dir. of Survey
Downstream
Length Surveyed
328.8 ft.
Total Length
328.8 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
186
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
186
Pipe schematic from manhole 18 0926 to 18 0925
MH: 18 0926MH: 18 0925downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 09260 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK11.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start28.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"32 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"77.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"149.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"319.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328.8 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK328.8 ft. MGO - General Observation - CAPPED LATERAL 9 O'CLOCK @ MH328.8 ft. AMH - Downstream Manhole, Survey Ends - 18 0925

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    11.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
77.9TF
149.6TB
0AMH18 0926
11.5CM
0MWL
32TF
74.6TFC
0MWM
28.3TFC
328.8MGOCONNECTION AT MH 3 O'CLOCK
328.8MGOCAPPED LATERAL 9 O'CLOCK @ MH
0MGOCONNECTION AT MH 9 O'CLOCK
319.3CM
328.8AMH18 0925

Properties (4)

additional_info
SC359667
custom_field_two
3
customer
LACSD
datetime
2018-06-28T02:38:32-07:00