Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 18, 2018, 04:14 PM
  • A 1167_A 1166_7182018_112145.mp4

Date
07/18/2018
W/O
0697985
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00973
PipeID
P02817
Time
9:14 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7760
Sewer Name
A JOINT OUTFALL A - UNIT 9
City
DOWNEY
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
20180718SHO_JOINT_OUTFALL_A_UNIT_9
Material
RCP-CTL
Shape
Circular
Height
42 in.
Upstream MH
A 1167
Downstream MH
A 1166
Dir. of Survey
Downstream
Length Surveyed
397.3 ft.
Total Length
397.3 ft.
Structural Index
5
Structural Quick
5631
Structural Rating
33
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
33
Pipe schematic from manhole A 1167 to A 1166
MH: A 1167MH: A 1166downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 11670 ft. MWM - Water Mark, 40 %of cross sectional area8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO10 ft. MGO - General Observation - MISSING TILES 100%19.4 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start52.8 ft. SRV - Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: NO194.7 ft. SRV - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Finish223.8 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO298.6 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO328.2 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO358.3 ft. MGO - General Observation - MISSING TILES 40%395.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish397.3 ft. AMH - Downstream Manhole, Survey Ends - A 1166

Observation photos (8)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

    8 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

  • General Observation - MISSING TILES 100%

    10 ft. - General Observation - MISSING TILES 100%

  • Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

    19.4 ft. - Surface Reinforcement Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

  • Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: NO

    52.8 ft. - Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    223.8 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

    298.6 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

    328.2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO

Observations (15)

DistanceCodeObservation
10MGOMISSING TILES 100%
19.4SRV
0MWL
358.3MGOMISSING TILES 40%
0AMHA 1167
0MWM
8SAP
328.2SRV
8SRV
395.3SAP
298.6SRV
52.8SRV
223.8SRV
397.3AMHA 1166
194.7SRV

Properties (4)

custom_field_three
SRV & SAP
custom_field_two
2
customer
LACSD
datetime
2018-07-18T09:14:10-07:00