02 1548_02 1547_27062018_025351.mp4
3.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
7.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
101.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 01 to 09 o'clock, , within 8 inches of joint: NO
127.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
137.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
150.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: NO
158.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
| Distance | Code | Observation |
|---|---|---|
| 0 | AMH | 02 1548 |
| 0 | MWL | — |
| 300.3 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 250 | TF | — |
| 0 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 158.4 | CM | — |
| 71.6 | TF | — |
| 298.3 | CM | — |
| 37.6 | TFC | — |
| 48 | TF | — |
| 270 | TFC | — |
| 7.5 | CM | — |
| 149.5 | TFA | — |
| 200.6 | TF | — |
| 137.8 | CM | — |
| 175.3 | TFA | — |
| 101.7 | DAE | — |
| 120.9 | TFC | — |
| 123.7 | TF | — |
| 172.4 | TFC | — |
| 220.6 | TFC | — |
| 74.2 | TF | — |
| 298.3 | DAGS | — |
| 0 | MWM | — |
| 223.9 | TF | — |
| 301.5 | AMH | 02 1547 |
| 267.3 | TFC | — |
| 3.7 | DAGS | — |
| 102.9 | TF | — |
| 150.8 | CL | — |
| 127.4 | CM | — |