Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2018, 09:04 AM
  • 02 0876_02 0875_06072018_022210.mp4

Date
07/06/2018
W/O
712060
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00249
PipeID
P03443
Time
2:04 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4005
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Maintenance Related
Project
WO_712060_TV02050_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0876
Downstream MH
02 0875
Dir. of Survey
Downstream
Length Surveyed
312.8 ft.
Total Length
312.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 02 0876 to 02 0875
MH: 02 0876MH: 02 0875downstream0 ft. MGO - General Observation - SERVICE CONNECTION AT 3 O' CLOCK AT MH0 ft. AMH - Upstream Manhole, Survey Begins - 02 08760 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area2.2 ft. MGO - General Observation - MAG COAT2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start9.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 8"53.2 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"85.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"99.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"143.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"163.1 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES163.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: YES, 6"186.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"288.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"311.3 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish312.8 ft. AMH - Downstream Manhole, Survey Ends - 02 0875

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 20 %of cross sectional area, from 08 to 09 o'clock,  , within 8 inches of joint: YES

    163.1 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES

Observations (17)

DistanceCodeObservation
0MGOSERVICE CONNECTION AT 3 O' CLOCK AT MH
288.1TFC
99.1TF
53.2TB
186.8TFC
2.2MGOMAG COAT
143.7TB
311.3SAV
2.2SAV
0AMH02 0876
85.1TFC
312.8AMH02 0875
0MWL
9.3TB
0MWM
163.2TB
163.1DAGS

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-07-06T02:04:31-07:00