Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 6, 2018, 10:12 AM
  • 02 0877_02 0876_06072018_032715.mp4

Date
07/06/2018
W/O
712060
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00249
PipeID
P03444
Time
3:12 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K4005
Sewer Name
02 DOWNEY TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Maintenance Related
Project
WO_712060_TV02050_JUL2018
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 0876
Downstream MH
02 0877
Dir. of Survey
Upstream
Length Surveyed
353.2 ft.
Total Length
353.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 02 0876 to 02 0877
MH: 02 0876MH: 02 0877upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 08770.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish6.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"42.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"142.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"242.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"295 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"341.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"350.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start350.7 ft. MGO - General Observation - MAG COAT353.2 ft. MWM - Water Mark, 50 %of cross sectional area353.2 ft. MGO - General Observation - SERVICE CONNECTION AT 9 O'CLOCK AT MH353.2 ft. MWL - Water Level, 25 %of cross sectional area353.2 ft. AMH - Downstream Manhole, Survey Begins - 02 0876

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
2.5SAV
0MWM
311.1TFC
2.5MGOMAG COAT
210.6TFC
0MGOSERVICE CONNECTION AT 9 O'CLOCK AT MH
11.6TFC
58.2TFC
353.2AMH02 0877
352.3SAV
347TFC
0MWL
0AMH02 0876
110.3TFC

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2018-07-06T03:12:27-07:00