- Date
- 06/15/2018
- W/O
- 707024
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00709
- PipeID
- P14719
- Time
- 1:09 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5198
- Sewer Name
- 18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 35
- Purpose
- Routine Assessment
- Project
- WO_707024_TV18101_JUN2018
- Sewer Type
- Siphon
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 48 in.
- Width
- 48 in.
- Upstream MH
- 18 0867
- Downstream MH
- 18 0866
- Dir. of Survey
- Downstream
- Length Surveyed
- 3.6 ft.
- Total Length
- 3.6 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 14
Pipe schematic from manhole 18 0867 to 18 0866 Observation photos (4)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES

3.6 ft. - Survey Abandoned - VIEW OF THE D/S SIPHON FROM THE U/S MH

3.6 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

3.6 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: NO