- Date
- 06/21/2018
- W/O
- 707209
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00006
- PipeID
- P25249
- Time
- 9:52 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5742
- Sewer Name
- 08 FIGUEROA STREET TRUNK
- City
- GARDENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- WO_707209_TV08173_JUN2018
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 08 0142
- Downstream MH
- 08 0141A
- Dir. of Survey
- Downstream
- Length Surveyed
- 123.3 ft.
- Total Length
- 123.3 ft.
- Structural Index
- 3
- Structural Quick
- 3D00
- Structural Rating
- 75
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 75
Pipe schematic from manhole 08 0142 to 08 0141A Observation photos (2)

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

114.9 ft. - Crack Multiple, from 12 to 12 o'clock, within 8 inches of joint: YES