Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2018, 05:47 AM
  • 19 0213_19 0212_13062018_230344.mp4

Date
06/13/2018
W/O
707048
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00718
PipeID
P15182
Time
10:47 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5729
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
WO_707048_TV19059_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0213
Downstream MH
19 0212
Dir. of Survey
Downstream
Length Surveyed
266.8 ft.
Total Length
266.8 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
120
O&M Index
2
O&M Quick
412J
O&M Rating
110
Overall Index
2
Overall Quick
Overall Rating
230
Pipe schematic from manhole 19 0213 to 19 0212
MH: 19 0213MH: 19 0212downstream0 ft. AMH - Upstream Manhole, Survey Begins - 19 02130 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start17.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"63 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start68.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"86.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"97.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"120.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"151.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"169.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"188.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"219 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"264.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish264.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish266.8 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK266.8 ft. AMH - Downstream Manhole, Survey Ends - 19 0212

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    63 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (20)

DistanceCodeObservation
188.4TFA
0AMH19 0213
264.5DAGS
219TFC
63CM
0MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
120.2TFC
266.8MGOACTIVE CONNECTION AT MH 9 O'CLOCK
169.7TFC
0MWL
17.2TFC
2DAGS
266.8AMH19 0212
68.2TFC
0MWM
151.4TF
97.2TFA
86.7TFA
0MGOCOCKROACHES IN MANHOLE
264.5CM

Properties (4)

additional_info
SC359395
custom_field_two
3
customer
LACSD
datetime
2018-06-13T22:47:49-07:00