Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 14, 2018, 05:23 AM
  • 19 0214_19 0213_13062018_224551.mp4

Date
06/13/2018
W/O
707048
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00718
PipeID
P15183
Time
10:23 PM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5729
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
WO_707048_TV19059_JUN2018
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0214
Downstream MH
19 0213
Dir. of Survey
Downstream
Length Surveyed
266.5 ft.
Total Length
266.5 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
141
O&M Index
2
O&M Quick
2J00
O&M Rating
108
Overall Index
2
Overall Quick
Overall Rating
249
Pipe schematic from manhole 19 0214 to 19 0213
MH: 19 0214MH: 19 0213downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 198 02140 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start18.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"28.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start78.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"89.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"108.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"130.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"140.3 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES141.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"184.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"195.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 4"230.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"264.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE264.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish264.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish266.5 ft. AMH - Downstream Manhole, Survey Ends - 19 0213266.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    28.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock,  , within 8 inches of joint: YES

    140.3 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 01 to 03 o'clock, , within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
264.6MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE
28.1CM
266.5AMH19 0213
0MWL
264.6CM
0MGOACTIVE CONNECTION AT MH 3 O'CLOCK
130.9TFC
18.7TFC
0AMH198 0214
2DAGS
78.4TF
230.6TFC
140.3DAGS
108.2TF
266.5MGOACTIVE CONNECTION AT MH 3 AND 9 O'CLOCK
0MWM
184.7TF
195.8TFA
89.2TF
141.5TFA
264.6DAGS

Properties (4)

additional_info
SC359395
custom_field_two
3
customer
LACSD
datetime
2018-06-13T22:23:07-07:00